100
109Design for easy maintenanceEasy Service & Maintenance Movable PCB panelEasier for maintenance work behind the PCB7-segment LEDEasy to read 7-se
110Heat pump : AJH040LCLAH / AJH045LCLAH / AJH054LCLAH Fujitsu General provides air conditioning systems for a wide range of applications from small o
111FeaturesHigh efficiencycompressor motorOptimized refrigerant flow designLow sound level designSignificantly low sound level is improved by using DC
112FeaturesLong piping lengthOur advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 80 m. This opens up
113Model : AJH040LCLAH / AJH045LCLAH / AJH054LCLAHSpecificationsDimensions(Unit : mm)Note : Specifications are based on the following conditions.Cooli
114FeaturesHeat pump : AJHA40LALH / AJHA45LALH / AJHA54LALHFujitsu General provides air conditioning systems for a wide range of applications from sma
115FeaturesPowerful HeatingHeating capacity is improved at low outdoor temperature by our advanced technology.7Current model (6HP class)16.6J-II serie
116FeaturesLong Piping LengthOur advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens u
117Model : AJHA40LALH / AJHA45LALH / AJHA54LALHSpecificationsDimensions(Unit : mm)Note : Specifications are based on the following conditions.Cooling
118FeaturesSmart and cutting edge designExtensive lineup from 8HP to 48HP in 2HP incrementConnectable indoor unit capacity ratio up to 150%Heat pumpEf
101AIRSTAGETM VRF Systems can be designed to effectively provide an air conditioning solution from a large domestic residence through to a large scale
119FeaturesSpace saving and compact sizeCompact size has been achieved by significantly reducing the width of the outdoor units compared to previous m
120FeaturesOverall piping length 1,000 mWorld’s top class overall piping length of 1,000 m allows for application in a wide variety of buildings.Desi
121More ComfortEasy Service & MaintenanceContinuous operation during maintenanceNon-stop operationWhen servicing a specific indoor unit, maintenan
122Outdoor units lineup•Combinations other than the followings are not recommended.Space saving combinationEnergy efficiency combination28.0 kW (10HP)
1238,10,12HP : AJHA72LALH / AJHA90LALH / AJH108LALH14,16HP : AJH126LALH / AJH144LALHDimensions(Unit : mm)Front side knockout positionAPower supply cab
124Outdoor units specificationsSpace Saving CombinationHPRating Capacity rangem3/hkWkWmmmmmmmmÛCW/WdB(A)kWCapacityPower sourcePakWkgkgCoolingHeatingCo
12536100.5112.528.86 27.84 3.484.0411,100 x 36365803.9 x 3 + 4.5 x 3Blue fin1,690 930 x 3765275 + 275 + 27511.8 x 319.0541.27-5 to 46-20 to 214850.3-1
126FeaturesHeat RecoveryN E WSmart and cutting edge designExtensive lineup from 8HP to 48HP in 2HP incrementConnectable indoor unit capacity ratio up
127FeaturesSophisticated operation controlWhen multiple outdoor units are connected, sophisticated operation is performed by each compressor. Efficien
128FeaturesOverall piping length 1,000 mHigh static pressure of 80PaLarge diameter fan and 3 phase DC motor has been utilized allowing an external sta
102Outdoor Units Line-up Page110~OUTLINEHeat Pump type for heating or cooling operationSystems for large homes to medium sized offices, shopsSlim Duc
129RB unitCeilingRB unit (single type)Flexible piping connectionA more flexible refrigerant piping work is possible by the use of various piping and R
130Outdoor units lineup•Combinations other than the followings are not recommended.Space saving combinationEnergy efficiency combination28.0 kW (10HP)
1318,10,12HP : AJHA72GALH / AJHA90GALH / AJH108GALH14,16HP : AJH126GALH / AJH144GALHDimensions(Unit : mm)Front side knockout positionAPower supply cab
132Outdoor units specificationsSpace Saving CombinationEnergy Efficiency Combination Note : Specifications are based on the following conditions.Cooli
13336100.5112.529.2528.863.443.9011,100×36466807.5×3Blue fin1,690930×3765286×311.8×319.0528.5841.27-10 to 46-20 to 21-10 to 215350.3-150.7AJH324GALHAJ
134Indoor Unit Lineup12 Types, 55 Models, Capacity range from 1.1 kW to 25.0 kWCassetteDuctCompact CassetteCassetteSlim Duct(With drain pump)Low Stati
1355.6187.12411.2369.03012.54514.05418.06022.47225.090AUXB18GALHAUXD18GALH AUXD24GALHAUXB24GALHAUXA45GALHAUXA36GALH AUXA54GALHAUXA30GALHARXC90GATH*ARX
136Indoor Units SpecificationsCompact Cassette2.22.825540450350343025AUXB07GALH1.11.323530420/450*1300/350*13428/30*121/25*1AUXB04GALH CoolingHeatingH
137Low Static Pressure Duct / Concealed Floor Slim Duct / Slim Concealed Floor 2.22.8463703102800 to 5025292624ARXB07GALHCoolingHeatingHighMed
138Indoor Units SpecificationsHigh Static Pressure DuctFloor / CeilingNote : Specifications are based on the following conditions. Cooling : Indoor te
103User's needs are supported by offering a variety of controls, such as individual control, central control, and building management control opt
139Wall MountedNote : Specifications are based on the following conditions. Cooling : Indoor temperature of 27ÛCDB / 19ÛCWB, and outdoor temperature o
140Air Conditioning Individual ControlService & Maintenance ToolSimple Remote ControllerUTY-RHKGWithoutoperation modeWireless Remote ControllerUTY
141Air Conditioning Centralized ControlConvertor / Adaptor (for external device)USB Adaptor*2Network ConvertorUTY-VGGXZ1System ControllerUTY-APGXUTY-A
142ControllerComparison table of ControllersMax. controllable remote controller groupsMax. controllable indoor units Max. controllable groups On / Off
143Easy operation by high-definition large STN-LCD touch panel screen• Easy finger touch operation with LCD panel• Built-in weekly/Daily timer(ON/OFF,
144ControllerN E WWired Remote Controller : UTY-RLRGHigh performance and compact sizeIn addition to the individual control, weekly timer, and various
145Compact remote controller provides access to basic functions• Up to 16 indoor units can be controlled with one remote controller.• Suitable for hot
146ControllerDC12 V is supplied by the indoor unit.Simple and sophisticated operations with a choice of 4 daily timers•A single controller controls up
147DC12 V is supplied by the indoor unit.Group control of indoor units with simple operation•Up to 8 remote controller groups can be controlled by one
148ControllerCentral Remote Controller fits small- and medium-sized buildings and tenants.• Individual control and monitor of 100 indoor units • 5 in
104Efficiency is improved significantly by using DC twin rotary compressor, inverter technology, and large heat exchangerHighly Energy EfficiencyHeat
149•Large-sized 7.5-inch TFT color•LCD Easy finger touch operation•Stylish shape and design to suit all application•No additional component is require
150ControllerSystem Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large sca
151Schedule managementDiverse operation management & Data managementError display & E-mail notificationError is notified with popup message, a
152ControllerRemote central controlBuilding Management Company A (In charge of the day shift)InternetorTelephone LineorLANInternetorTelephone LineorLA
153FUNCTIONS SUMMARY• Microsoft® Windows Vista® Home Premium (32-bit) SP2, Windows Vista® Business (32-bit) SP2• Microsoft® Windows® 7 Home Premium (3
154Adaptor & Convertor• It is possible to connect medium to large sized BMS to VRF network system via BACnet®, a global standard for open networks
155Max.controllable128indoor unitsMax.controllable4units to BMSInstallation exampleGeneral-purpose building control computer( devi
156Adaptor & ConvertorSpecificationsMODBUS® Interface : FJ-RC-MBS-1The MODBUS Interface allows a complete integration of air conditioners into MO
157Wireless LAN Interface : FJ-RC-WIFI-1N E WSpecificationsModel nameDimensions (H x W x D) (mm)Weight (g)FJ-RC-WIFI-170×108×2880SmartphoneTabletPCSma
158Adaptor & Convertor•Transmission Line length can be extended up to 3,600m with multiple Signal Amplifiers.•Up to 8 signal amplifiers can be ins
105Quiet operationTwo low noise modes can be selected automatically by quiet priority setting and capacity priority setting depending on the indoor en
159•This network convertor is to be used for connecting single split system or group remote controller with the VRF network system.•Please select the
160Service & MaintenanceExtensive monitoring and analysis functions for installation and maintenance•Operation status can be checked and analyzed
161Indoor unitMax. 400VRF NetworkSystem 2Indoor unitMax. 400VRF NetworkSystem 3Indoor unitMax. 400VRF NetworkSystem 4Indoor unitMax. 400VRF NetworkSys
170OPTIONAL PARTS for VRFConnection UnitsFor Compact Wall Mounted typeUTP-AX090AUTP-AX567AUTP-AX180AUTP-BX090AUTP-BX567AUTP-BX180AUTR-H0906L / UTR-H18
171Specifications*1: In case of two RB units connected in series ( total 8-branches ), maximum capacity of connectable indoor units is up to 56.0 kW.k
172Wired Remote ControllerOPTIONAL PARTS for VRFSimple Remote ControllerUTY-RSKGWith operation modeSimple Remote ControllerUTY-RHKGWithout operation m
173Wireless LAN InterfaceFJ-RC-WIFI-1MODBUS® InterfaceFJ-RC-MBS-1Network ConvertorUTY-VGGXZ1Network Convertorfor LONWORKS®UTY-VLGXExternal Switch Cont
174OPTIONAL PARTS for VRFFor Indoor unitUTY-XWZXZ7UTY-XWZXZBUTY-XWZXZCUTY-XWZXZDUTY-XWZXZEFor Outdoor unitUTY-XWZXZ6UTY-XWZXZ9For RB unitUTY-XWZXZ6For
175Flange (Round)UTD-RF204Flange (Square)Long-Life FilterUTD-SF045TDrain Pump UnitUTD-LF60KA UTZ-PX1BBAUTZ-PX1NBAFor Ceiling typeDrain Pump UnitUTR-DP
190TitleComfortable FunctionConvenient FunctionDouble swing automaticComplex swing action of flaps enables automatically to swing both horizontal and
106FeaturesHigh capacity connectionDesign FlexibilityInstallation in extreme temperature conditions is possible due to an increase in operational rang
191Feature SummaryComfortable functionConvenient functionClean functionUp / down swing flapsWall MountedFloorCompact Cassette / CassetteFloor/Ceiling
107Liquid flow back protectionBy adopting a large sized accumulator, not completely vapourised refrigerant stays inside of the accumulator to ensure n
108FeaturesEasily transportedSimple wiring workInstallation of the wiring systems is made easier as the communication wiring can be installed continuo
Kommentare zu diesen Handbüchern